LOGIN JOIN ADMIN
 
 
PsyORD(»çÀÌ¿À´õ)
ÀζóÀÎ °Ë»ç½Ã½ºÅÛ
PsyPOD(»çÀÌÆ÷µå)
¼ÒÀ½Áøµ¿°èÃø±â,³»±¸¸ð´ÏÅ͸µ
PsyREC(»çÀÌ·¹ÄÚ´õ)
µ¥ÀÌÅÍ ·¹ÄÚµù ¹× ÈÄ󸮺м®
PsyBAL(»çÀ̹߶õ½Ì)
¹ß¶õ½Ì ¾îÇø®ÄÉÀ̼Ç
PsyDATA(»çÀ̵¥ÀÌÅÍ)
µ¥ÀÌÅͺ£À̽º ¹× Áø´ÜºÐ¼®
Sub Program
º¸Á¶ ÇÁ·Î±×·¥
Bio-Potential Amplifier
»ýü°èÃø¸ðµâ
MRE
ÀÚ±â°ø¸í ź¼º°è¼ö ¿µ»ó¹ý
PsyDAQ(»çÀ̵¦)
¿£Áø ´ÙÀ̳ª¸ð¸ÞÅÍ Á¦¾î
Fuel Cell Control
¿¬·áÀüÁö Á¦¾î
Nano Spindle Analyzer
³ª³ë½ºÇÉµé ºÐ¼®±â
Press Force Analyzer
±ÝÇü¾Ð·Â ÃøÁ¤½Ã½ºÅÛ
Tension Measurement System
Àå·Â ÃøÁ¤½Ã½ºÅÛ
Equipment & Sensor
ÃøÁ¤±â ¹× ¼¾¼­
 
 
 


Tension Measurement System / Àå·ÂÃøÁ¤½Ã½ºÅÛ

Àå·ÂÃøÁ¤½Ã½ºÅÛÀº Rolling Printing Àåºñ µî¿¡¼­ Çʸ§ÀÌ ´ç°ÜÁú ¶§ µÎ °³ÀÇ ·Ñ·¯ »çÀÌÀÇ Çʸ§¿¡ ÀÛ¿ëÇÏ´Â Àå·ÂÀ» ÃøÁ¤ÇÏ´Â ½Ã½ºÅÛ ÀÔ´Ï´Ù. Trigger¿¡ ÀÇÇÑ ¹Ýº¹ ÃøÁ¤ÀÌ °¡´ÉÇÏ¿© Auto Feeding ÀåÄ¡ÀÇ ¹Ýº¹¼º´ÉÀ» Æò°¡ÇÒ ¼ö ÀÖ½À´Ï´Ù. ¶ÇÇÑ, Àå½Ã°£ ·¹ÄÚµù ±â´ÉÀ» °®Ãß°í ÀÖ¾î Feeding ½Ã½ºÅÛÀÇ ¾ÈÁ¤¼ºÀ» °ËÁõÇÏ´Â µ¥µµ »ç¿ëµË´Ï´Ù.

[Tension Measurement System]


[Àå·ÂÃøÁ¤ ¼ÒÇÁÆ®¿þ¾î]


[Àå·ÂÃøÁ¤ ¼ÒÇÁÆ®¿þ¾î]

Hardware Specification

Items

Specifications

A/D Resolution

16-bit

Number of Channel

3ch

Sampling Rate

1000Hz

Measurement Duration

1~5 sec

Tension Transducer

2ch Amplifier
Output (V)4point, (A)2Point

Digital Trigger Module

1ch Fiberoptic Sensor
Response : 20 ¥ìs ~50 ¥ìs

Interface

USB bus

Software Features

- Digital Trigger
- Digital Filter (butterworthlowpass filter)
- Save / Load / ASCII Export
- Signal Monitoring
- Long Time Recording
- Feature Extraction (Peak, Min, Max, Standard deviation)